Configure HVAC Equipment and Air Handlers With Verified Performance
An HVAC and air handler configurator lets reps and application engineers select tonnage, coils, blower and motor, controls, and voltage for air handlers, rooftop units, and condensers, while the engineering rules confirm airflow, return the resulting SEER2 and EER, and price the unit so every quote is technically valid.
Every HVAC Specification, Engineered Right
The real selections behind an air handler or rooftop unit
Tonnage & Capacity
Size by nominal tonnage or BTU/h cooling and heating load, with the configurator matching coil and compressor capacity to the entered requirement.
Coils
Evaporator and condenser coil rows, fin spacing, circuiting, copper or aluminum microchannel, and coating options for corrosive environments.
Ducting & Airflow
Supply and return configuration, CFM, external static pressure, filter racks, economizers, and dampers validated against the blower curve.
Efficiency Ratings
Live SEER2, EER, IEER, and AFUE for the configuration, with checks against DOE minimums and ENERGY STAR thresholds.
Controls
Thermostats, BACnet and Modbus building-management integration, VFD blowers, demand control ventilation, and smart sensors.
Voltage & Electrical
208/230V, 460V, single or three phase, with automatic MCA and MOCP calculation and compatible motor and heater selection.
Why HVAC Manufacturers Configure
Quote complex equipment without an engineer on every call
Performance You Can Stand Behind
SEER2, airflow, and capacity are computed from the actual selections, so quoted ratings match the unit you ship.
Reps Quote Without Engineering
The rules engine carries the application logic, freeing your engineers from routine selection requests.
No Electrical Mismatches
Voltage, phase, motor, and heater compatibility is enforced, eliminating field failures and warranty claims.
Shop-Ready Documentation
Each order produces a submittal, wiring diagram, and BOM. See how it fits the wider manufacturing configurator.
From Load Calc to Submittal
Connect configuration to engineering, pricing, and production
Engineering & Ratings
- Capacity and airflow matching
- SEER2 / EER / IEER calculation
- MCA and MOCP electrical sizing
- Static pressure validation
- DOE and ENERGY STAR checks
Submittal Output
- Submittal data sheets
- Wiring diagrams
- Bills of materials
- Dimensional drawings
- AHRI rating references
Business Systems
- ERP integration
- CPQ quoting
- Rep and distributor portals
- BMS / controls catalogs
- Order management
New to this? Read what is a product configurator or learn what is CPQ software.
Configuring an air handler, rule by rule
What an air handler configurator actually checks between the first selection and the quote
An air handler quote starts from airflow. The rep enters the design CFM and external static pressure, and the rules narrow the cabinet sizes that can carry that airflow. Coil selection follows: rows, fin spacing and circuiting set capacity, and a face-velocity rule keeps the coil below the limit your engineering team uses to avoid moisture carryover. Fan and motor come next, sized against total static pressure including the coil, filters and any added sections, with the motor matched to the voltage and phase the site has.
Options are where manual quotes go wrong. An economizer, a heating coil, a UV section or a higher filter class each change the static pressure, the length of the unit and sometimes the electrical load. In a configurator each option re-runs the rules, so adding a MERV 13 filter bank that pushes the fan past its curve shows up as a blocker at selection time, not as a callback after the unit ships.
The rules and limits are yours. Ignitionary encodes the selection data, fan curves and limits your engineers already use; it does not replace AHRI-certified rating software, and published ratings still come from your certified tools. What it removes is the back-and-forth between sales and application engineering for units that fall inside rules you have already written down.
The same approach works for rooftop units and condensers. For wider context, see industrial equipment configuration, how rules-based CPQ prices the result, and the heating element manufacturer's results from encoding 200+ engineering formulas.

Refrigerated and cooking equipment for commercial kitchens follows the same approach; see the foodservice equipment configurator.
Frequently asked questions
An HVAC configurator is software that lets reps and engineers select tonnage or capacity, coil rows, blower and motor, controls, and voltage for air handlers, rooftop units, and condensers. It validates that the combination is engineering-valid, returns the resulting SEER2 or EER and airflow, and prices the unit with all accessories in one pass.
Yes. When the user enters required capacity, the configurator sizes coil rows and fin spacing, selects a compatible blower and motor, and confirms the CFM and external static pressure are within the unit's operating envelope. Mismatched coil, fan, and tonnage selections are blocked so quoted performance matches what the equipment can actually deliver.
It does. The rules engine ties voltage and phase (208/230V single phase, 460V three phase, and others) to compatible motors, heaters, and controls, then computes MCA and MOCP for the configuration. Incompatible electrical selections are flagged at selection time, preventing field issues and rework after the unit ships.
An air handler configurator is software that builds a valid air handling unit from airflow, static pressure and options: cabinet size, coil, fan and motor, filters, and added sections such as economizers or heating coils. Engineering rules check each combination, and the configurator prices the unit and produces the quote and submittal data.
Yes, as rules you define. Face velocity is calculated from the design airflow and coil face area and compared with your limit, and total static pressure is summed from the selected sections and checked against the fan curve data you provide. A selection that breaks either rule is blocked with the value and the limit shown.
No. Certified ratings still come from your certified selection tools. The configurator encodes your selection data and limits so reps can quote units that fall inside them without waiting for application engineering, and it hands off to engineering when a request falls outside.
Quote HVAC Equipment That Performs as Promised
See how Ignitionary turns tonnage, coils, and controls into validated, accurate quotes.